Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://bdtd.unifal-mg.edu.br:8443/handle/tede/613
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCOELHO, Mariny Fabiéle Cabral-
dc.creator.Latteshttp://lattes.cnpq.br/5170348815353458por
dc.contributor.advisor1MARIANO, Neide Aparecida-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0809795245116090por
dc.contributor.referee1CARABALLO, Mirta Mir-
dc.contributor.referee2RIGO, Eliana Cristina da Silva-
dc.date.accessioned2015-07-17T19:37:30Z-
dc.date.issued2013-07-29-
dc.identifier.citationCOELHO, Mariny Fabiéle Cabral. Recobrimento biomimético em superfícies de titânio e aço inoxidável austenítico. 2013. 83 f. Dissertação (Mestrado em Ciência e Engenharia de Materiais) - Universidade Federal de Alfenas, Poços de Caldas, MG, 2013.por
dc.identifier.urihttps://bdtd.unifal-mg.edu.br:8443/handle/tede/613-
dc.description.resumoO titânio e o aço inoxidável são exemplos de biomateriais muito utilizados em implantes dentários e ortopédicos, por apresentarem características para essa aplicação, como resistência à corrosão e excelente biocompatibilidade. Pesquisas vêm sendo realizadas para a obtenção de um recobrimento, visando melhorar a adesão entre o osso e o implante, através da modificação da superfície do metal, permitindo uma eficaz regeneração do tecido ósseo, osseointegração e aceleração do seu crescimento. Neste trabalho, estudou-se o efeito do recobrimento do método biomimético sobre o titânio (Ti c.p.) e o aço inoxidável AISI 316L, que consiste na imersão do substrato, em uma solução sintética de SBF (Simulated Body Fluid), de composição, pH e temperatura semelhantes ao plasma sanguíneo. O recobrimento sobre ambos os metais, mostraram-se eficiente para obtenção de hidroxiapatita, sendo confirmada através das técnicas de MEV, DRX e infravermelho. O ensaio de bioatividade revelou ótimas características bioativas através da formação e desenvolvimento da hidroxiapatita sobre os substratos que receberam o recobrimento com 1,5 SBF. Para os substratos de Ti c.p. e aço inoxidável austenítico 316L que não receberam tratamento prévio ou recobrimento, o ensaio de bioatividade revelou a bioatividade somente do Ti c.p.. As curvas de polarização revelaram que o Ti c.p. sem recobrimento e o aço inoxidável austenítico 316L com recobrimento apresentaram melhores resistência à corrosão para as temperaturas de 25 e 36,5ºC. O titânio sem recobrimento apresentou-se como o biomaterial mais indicado para implantes, já que apresentou melhores características bioativas e resistência à corrosão.por
dc.description.abstractTitanium and stainless steel are examples of biomaterials widely used in dental and orthopedic implants, due to their characteristics for this application, such as corrosion resistance and excellent biocompatibility. Researches have been performed to obtain a coating in order to improve the adhesion between the bone and implant by modifying the metal surface, allowing for effective regeneration of bone tissue, osseointegration, and accelerating its growth. In this work, studied the effect of coating of biomimetic method on titanium (cp-Ti) and AISI 316L stainless steel, which consists in immersing the substrate in a solution of synthetic SBF (Simulated Body Fluid), composition, pH and temperature similar to blood plasma. The coating on both metals, was effective for obtaining hydroxyapatite, which was confirmed through the techniques of SEM, XRD and infrared. The bioactivity test showed excellent bioactive characteristics through of formation and development of hydroxyapatite on the receiving coating substrates with 1.5 SBF. For the substrates, cp-Ti and 316L austenitic stainless steel that have not received prior treatment or coating, the bioactivity test revealed only the bioactivity of cp-Ti. The polarization curves showed that the uncoated cp-Ti and 316L austenitic stainless steel with coating had better corrosion resistance at temperatures of 25ºC and 36.5°C. The uncoated cp-Ti showed as the most indicated biomaterial for implants, since it showed better bioactive characteristics and corrosion resistance.por
dc.description.provenanceSubmitted by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2015-07-13T18:31:03Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DISSERTAÇÃO Mariny Fabiele Cabral Coelho 2013.pdf: 2314344 bytes, checksum: 44d8f05e7f10a7600544cead52d23304 (MD5)eng
dc.description.provenanceApproved for entry into archive by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2015-07-17T15:39:10Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DISSERTAÇÃO Mariny Fabiele Cabral Coelho 2013.pdf: 2314344 bytes, checksum: 44d8f05e7f10a7600544cead52d23304 (MD5)eng
dc.description.provenanceApproved for entry into archive by Thaís Aparecida de Lima (thais.aplima@unifal-mg.edu.br) on 2015-07-17T19:37:14Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DISSERTAÇÃO Mariny Fabiele Cabral Coelho 2013.pdf: 2314344 bytes, checksum: 44d8f05e7f10a7600544cead52d23304 (MD5)eng
dc.description.provenanceMade available in DSpace on 2015-07-17T19:37:30Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DISSERTAÇÃO Mariny Fabiele Cabral Coelho 2013.pdf: 2314344 bytes, checksum: 44d8f05e7f10a7600544cead52d23304 (MD5) Previous issue date: 2013-07-29eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal de Alfenaspor
dc.publisher.departmentInstituto de Ciência e Tecnologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIFAL-MGpor
dc.publisher.programPrograma de Pós-Graduação em Ciência e Engenharia de Materiaispor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectAço inoxidávelpor
dc.subjectTitâniopor
dc.subjectHidroxiapatitapor
dc.subject.cnpqENGENHARIA DE MATERIAIS E METALURGICA::METALURGIA FISICApor
dc.titleRecobrimento biomimético em superfícies de titânio e aço inoxidável austeníticopor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DISSERTAÇÃO Mariny Fabiele Cabral Coelho 2013.pdfRecobrimento biomimético em superfícies de titânio e aço inoxidável austenítico 2,26 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons